150 Ton Hydraulic Laboratory Press

Load capacity: Adjustable 10 ton - 150 ton (100kN - 1500kN)
Platen size: 596mm x 596 mm | 23.46 x 23.46 in with additional size options
Daylight Layer Options: Single | Double | Triple

Featuring unmatched heat stability and force control, the 150 ton (1500 kN) elastomer press is designed for high capacity laboratory molding or light production.

   Download Brochure    Request Quote

150 Ton Hydraulic Laboratory Press

The 1500 kN rubber laboratory press is designed to accommodate larger molds and lighter scale production. Featuring the best insulation, platen parallelism, heat stability and data collection software, the 1500kN press is compliant to the strictest laboratory press standards making it the top-tier press for R&D.

Features

  • Complete compliance with ASTM D3182 or ISO 2393
  • Adjustable press force 100kN – 1500kN | 10 ton – 150 ton
  • Digitally controlled force and speed
  • High-speed hydraulics
  • Single daylight access
  • Small footprint for benchtop use
  • Temperature accuracy of ± 0.5°C
  • Digital PID-controlled heating systems
  • Platen parallelism better than 0.1 mm/m.
  • Air cooled heat exchange
  • Programmable operator display
  • Pneumatic front shield
  • Front-side mold access
  • Over a dozen customizable safety features

Platen Options

  • Custom platen sizes and additional heating zones
  • Increased Platen Temperature Ranges
  • Software programmable heating and platen cooling
  • Water cooling platens
  • Additional heating options: Steam or oil
  • Heater timers and cycle counters

Hydraulic Options

  • Low pressure press systems
  • Increased hydraulic cylinder stroke
  • Electronically controlled contact gauge for increased energy efficiency and press noise reduction
  • Custom ejection cylinders for molded part removal

Mechanical Options

  • Press down acting options
  • Custom Tie Rods
  • Automated platen shuttles
  • Multiple daylight Options
  • Sliding or tilting platens
  • Custom Mold mounts
  • Platen ejection systems
  • Work tables

Electrical Options

  • Data interface - MonPress
  • Light Curtains
  • Alarm systems
  • Mold heat temperature controllers
  • Platen Display Lighting
Lab Press 1500kn
Lab Press Platen

Technical Specifications

Standards

Fully compliant with ISO, DIN, ASTM and GB Standards

Load Capacity Range

100kN - 1500kN (10 - 150 ton)

Hydraulic Pressure

28 - 400 bar (oil capacity of the press: ≈22 liters, highly energy efficient)

Platen Dimensions

596mm x 596 mm | 23.46 x 23.46 in (larger platens available upon request)

Specific Press Pressure
(based on plate dimensions)

4.22 N/mm2

Pneumatics

4.5 bar

Daylight Options

Single | Double | Triple

Maximum Single Daylight Stroke

300 mm

Maximum Double Daylight Stroke

100mm each

Double Acting Press Cylinder

⌀240 mm

Ram Diameter

⌀ 80mm with 400mm flange

Closing Speed

≈20mm/s

Opening Speed

≈16mm/s

Heating Type

Electrical

Temperature
(individually PID controlled)

250°C (increased temperature capacity available upon request)

Electrical Safety & Isolators

MCBs and interlocks

Mechanical Safety

Automated safety shield (other options available upon request)

Operator Control

PLC, 5.7" digital interface

Pressing Speed

≈1.2 to 2 mm/s

Connected load of the press

34kW

Power Connection

400 V triple phase | 50/60Hz ≈100 Amps with neutral ground

Press Dimensions (H x W x D)

70.87 in x 77.95 in x 47.24 in (1800 mm x 1980 mm x 1200 mm)

Press Weight

1400kg

Foundation Requirements

Even lab floor with two tons / m3 capacity